HEN0510

HEN0510 Non-Insulated Bootlace Ferrule: 0.5 mm² / 22 AWG 10 mm Barrel

The HEN0510 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 0.5 mm² stranded conductor where no insulating collar is required.

  • Wire size0.5 mm² / catalogue reference 22 AWG
  • Barrel length10 mm / 0.39 in
  • CollarNone – bare tin plated sleeve
  • Rating9 A catalogue maximum
  • ComplianceCE and RoHS; not UL Listed
  • Pack2,000 pieces
Verified modelDimensions and pack quantity match the HEN0510 supplier specification.
Catalogue configurationThe sleeve is shown for catalogue reference; availability, pack quantity and lead time are confirmed by quotation.
Crimp toolSN-06WF covers the 0.5 mm² ferrule range.

HEN0510 wire ferrule dimensions and specifications

Property HEN0510 value
Product type Non-insulated ferrule / bare bootlace sleeve
Conductor cross-section 0.5 mm²
Catalogue AWG reference 22 AWG
Barrel length (F) 10.0 mm / 0.39 in
Overall length (L) 10.0 mm / 0.39 in
Flare outside diameter (W) 1.7 mm / 0.07 in
Barrel outside diameter (D) 1.3 mm / 0.05 in
Barrel inside diameter (C) 1.0 mm / 0.04 in
Barrel material Copper, tin plated
Catalogue current rating 9 A
Compliance CE and RoHS; not UL Listed
Pack quantity 2,000 pcs

The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN0510 from the conductor’s marked 0.5 mm² cross-section first, then compare a 10 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.


0.5 mm² bare ferrule with a 10 mm barrel

The model code is direct: 05 identifies the 0.5 mm² conductor size and 10 identifies the nominal barrel length in millimetres. HEN0510 suits terminals that accept a 10 mm barrel.

Compliance and ordering

HEN0510 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN0510 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.

Request HEN0510 pricing

Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.

FAQ

What does HEN0510 mean?

HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 05 size code identifies the 0.5 mm² conductor size and 10 denotes a 10 mm barrel.

When is a non-insulated ferrule the right choice?

Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.

Is HEN0510 UL Listed?

No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.

Is HEN0510 a bootlace ferrule?

Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.

Which crimp tool covers HEN0510?

SN-06WF covers the 0.5 mm² range that includes HEN0510. Verify the finished crimp against the conductor and terminal requirements.

Is HEN0510 sold individually?

No. The standard factory pack contains 2,000 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.