HEN1006

HEN1006 Non-Insulated Bootlace Ferrule: 1 mm² / 18 AWG 6 mm Barrel

The HEN1006 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 1 mm² stranded conductor where no insulating collar is required.

  • Wire size1 mm² / catalogue reference 18 AWG
  • Barrel length6 mm / 0.24 in
  • CollarNone – bare tin plated sleeve
  • Rating17 A catalogue maximum
  • ComplianceCE and RoHS; not UL Listed
  • Pack2,000 pieces
Verified modelDimensions and pack quantity match the HEN1006 supplier specification.
Catalogue configurationThe sleeve is shown for catalogue reference; availability, pack quantity and lead time are confirmed by quotation.
Crimp toolSN-06WF covers the 1 mm² ferrule range.

HEN1006 wire ferrule dimensions and specifications

Property HEN1006 value
Product type Non-insulated ferrule / bare bootlace sleeve
Conductor cross-section 1 mm²
Catalogue AWG reference 18 AWG
Barrel length (F) 6.0 mm / 0.24 in
Overall length (L) 6.0 mm / 0.24 in
Flare outside diameter (W) 2.2 mm / 0.09 in
Barrel outside diameter (D) 1.8 mm / 0.07 in
Barrel inside diameter (C) 1.4 mm / 0.06 in
Barrel material Copper, tin plated
Catalogue current rating 17 A
Compliance CE and RoHS; not UL Listed
Pack quantity 2,000 pcs

The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN1006 from the conductor’s marked 1 mm² cross-section first, then compare a 6 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.


1 mm² bare ferrule with a 6 mm barrel

The model code is direct: 10 identifies the 1 mm² conductor size and 6 identifies the nominal barrel length in millimetres. HEN1006 suits terminals that accept a 6 mm barrel.

Compliance and ordering

HEN1006 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN1006 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.

Request HEN1006 pricing

Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.

FAQ

What does HEN1006 mean?

HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 10 size code identifies the 1 mm² conductor size and 6 denotes a 6 mm barrel.

When is a non-insulated ferrule the right choice?

Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.

Is HEN1006 UL Listed?

No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.

Is HEN1006 a bootlace ferrule?

Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.

Which crimp tool covers HEN1006?

SN-06WF covers the 1 mm² range that includes HEN1006. Verify the finished crimp against the conductor and terminal requirements.

Is HEN1006 sold individually?

No. The standard factory pack contains 2,000 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.