HEN1012
HEN1012 Non-Insulated Bootlace Ferrule: 1 mm² / 18 AWG 12 mm Barrel
The HEN1012 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 1 mm² stranded conductor where no insulating collar is required.
- Wire size1 mm² / catalogue reference 18 AWG
- Barrel length12 mm / 0.47 in
- CollarNone – bare tin plated sleeve
- Rating17 A catalogue maximum
- ComplianceCE and RoHS; not UL Listed
- Pack2,000 pieces
HEN1012 wire ferrule dimensions and specifications
| Property | HEN1012 value |
|---|---|
| Product type | Non-insulated ferrule / bare bootlace sleeve |
| Conductor cross-section | 1 mm² |
| Catalogue AWG reference | 18 AWG |
| Barrel length (F) | 12.0 mm / 0.47 in |
| Overall length (L) | 12.0 mm / 0.47 in |
| Flare outside diameter (W) | 2.2 mm / 0.09 in |
| Barrel outside diameter (D) | 1.8 mm / 0.07 in |
| Barrel inside diameter (C) | 1.4 mm / 0.06 in |
| Barrel material | Copper, tin plated |
| Catalogue current rating | 17 A |
| Compliance | CE and RoHS; not UL Listed |
| Pack quantity | 2,000 pcs |
The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN1012 from the conductor’s marked 1 mm² cross-section first, then compare a 12 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.
1 mm² bare ferrule with a 12 mm barrel
The model code is direct: 10 identifies the 1 mm² conductor size and 12 identifies the nominal barrel length in millimetres. HEN1012 suits terminals that accept a 12 mm barrel.
Compliance and ordering
HEN1012 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN1012 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.
Request HEN1012 pricing
Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.
FAQ
What does HEN1012 mean?
HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 10 size code identifies the 1 mm² conductor size and 12 denotes a 12 mm barrel.
When is a non-insulated ferrule the right choice?
Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.
Is HEN1012 UL Listed?
No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.
Is HEN1012 a bootlace ferrule?
Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.
Which crimp tool covers HEN1012?
SN-06WF covers the 1 mm² range that includes HEN1012. Verify the finished crimp against the conductor and terminal requirements.
Is HEN1012 sold individually?
No. The standard factory pack contains 2,000 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.