
HEN2518
HEN2518 Non-Insulated Bootlace Ferrule: 2.5 mm² / 14 AWG 18 mm Barrel
The HEN2518 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 2.5 mm² stranded conductor where no insulating collar is required.
- Wire size2.5 mm² / catalogue reference 14 AWG
- Barrel length18 mm / 0.71 in
- CollarNone – bare tin plated sleeve
- Rating30 A catalogue maximum
- ComplianceCE and RoHS; not UL Listed
- Pack1,000 pieces
HEN2518 wire ferrule dimensions and specifications
| Property | HEN2518 value |
|---|---|
| Product type | Non-insulated ferrule / bare bootlace sleeve |
| Conductor cross-section | 2.5 mm² |
| Catalogue AWG reference | 14 AWG |
| Barrel length (F) | 18.0 mm / 0.71 in |
| Overall length (L) | 18.0 mm / 0.71 in |
| Flare outside diameter (W) | 3.3 mm / 0.13 in |
| Barrel outside diameter (D) | 2.6 mm / 0.10 in |
| Barrel inside diameter (C) | 2.3 mm / 0.09 in |
| Barrel material | Copper, tin plated |
| Catalogue current rating | 30 A |
| Compliance | CE and RoHS; not UL Listed |
| Pack quantity | 1,000 pcs |
The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN2518 from the conductor’s marked 2.5 mm² cross-section first, then compare an 18 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.
2.5 mm² bare ferrule with an 18 mm barrel
The model code is direct: 25 identifies the 2.5 mm² conductor size and 18 identifies the nominal barrel length in millimetres. HEN2518 suits terminals that accept an 18 mm barrel.
Compliance and ordering
HEN2518 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN2518 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.
Request HEN2518 pricing
Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.
FAQ
What does HEN2518 mean?
HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 25 size code identifies the 2.5 mm² conductor size and 18 denotes an 18 mm barrel.
When is a non-insulated ferrule the right choice?
Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.
Is HEN2518 UL Listed?
No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.
Is HEN2518 a bootlace ferrule?
Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.
Which crimp tool covers HEN2518?
SN-06WF covers the 2.5 mm² range that includes HEN2518. Verify the finished crimp against the conductor and terminal requirements.
Is HEN2518 sold individually?
No. The standard factory pack contains 1,000 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.
Related ferrules
