HTE6014

HTE6014 Twin Bootlace Ferrule: 2×6 mm² / 10 AWG Yellow, 14 mm Pin

The HTE6014 twin wire ferrule is an insulated bootlace ferrule that terminates two 6 mm² stranded conductors in one barrel, so a single crimp enters the terminal.

  • Wire size2×6 mm² / catalogue reference 10 AWG
  • Pin length14 mm / 0.55 in
  • CollarYellow, DIN colour configuration
  • Rating50 A catalogue maximum
  • ComplianceCE and RoHS; not UL Listed
  • Pack500 pieces
Verified modelDimensions and pack quantity match the HTE6014 supplier specification.
Catalogue configurationThe yellow configuration is shown for catalogue reference; availability, pack quantity and lead time are confirmed by quotation.
Crimp toolSN-06WF covers the 6 mm² ferrule range.

HTE6014 wire ferrule dimensions and specifications

Property HTE6014 value
Product type Twin insulated ferrule / twin bootlace ferrule
Conductor cross-section 2×6 mm²
Catalogue AWG reference 10 AWG
Pin / barrel length (F) 14.0 mm / 0.55 in
Overall length (L) 26.1 mm / 1.03 in
Collar width (W) 9.5 mm / 0.37 in
Collar height (H) 12.1 mm / 0.48 in
Barrel outside diameter (D) 5.3 mm / 0.21 in
Barrel inside diameter (C) 4.9 mm / 0.19 in
Collar colour shown Yellow
Alternative factory colours Green or Black; confirm when ordering
Barrel material Copper, tin plated
Collar material PA66 nylon, halogen-free
Maximum operating temperature 105 °C
Catalogue current rating 50 A
Compliance CE and RoHS; not UL Listed
Pack quantity 500 pcs

The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HTE6014 from the conductor’s marked 2×6 mm² cross-section first, then compare a 14 mm pin with the terminal maker’s accepted ferrule and strip-length requirements.


2×6 mm² yellow ferrule with a 14 mm pin

The model code is direct: 60 identifies the 6 mm² conductor size and 14 identifies the nominal pin length in millimetres. HTE6014 suits terminals that accept a 14 mm pin.

Compliance and ordering

HTE6014 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the twin range is outside it. HTE6014 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.

Request HTE6014 pricing

Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.

FAQ

What does HTE6014 mean?

HTE identifies the insulated twin ferrule series, which terminates two conductors in one barrel. The 60 size code identifies the 6 mm² size of each conductor and 14 denotes a 14 mm pin.

Why use a twin ferrule instead of two single ferrules?

A twin ferrule brings two conductors into one terminal in a single crimp. Forcing two separate ferrules into one terminal risks an uneven clamp.

Is HTE6014 UL Listed?

No. The supplier confirms UL 486F covers the HE single-wire series only; the HTE twin series is not UL Listed. It is supplied with CE and RoHS documentation.

Is HTE6014 a bootlace ferrule?

Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.

Which crimp tool covers HTE6014?

SN-06WF covers the 6 mm² range that includes HTE6014. Verify the finished crimp against the conductor and terminal requirements.

Is HTE6014 sold individually?

No. The standard factory pack contains 500 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.