HEN95-34
HEN95-34 Non-Insulated Bootlace Ferrule: 95 mm² / 3/0 AWG 34 mm Barrel
The HEN95-34 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 95 mm² stranded conductor where no insulating collar is required.
- Wire size95 mm² / catalogue reference 3/0 AWG
- Barrel length34 mm / 1.34 in
- CollarNone – bare tin plated sleeve
- Rating310 A catalogue maximum
- ComplianceCE and RoHS; not UL Listed
- Pack100 pieces
HEN95-34 wire ferrule dimensions and specifications
| Property | HEN95-34 value |
|---|---|
| Product type | Non-insulated ferrule / bare bootlace sleeve |
| Conductor cross-section | 95 mm² |
| Catalogue AWG reference | 3/0 AWG |
| Barrel length (F) | 34.0 mm / 1.34 in |
| Overall length (L) | 34.0 mm / 1.34 in |
| Flare outside diameter (W) | 17.3 mm / 0.68 in |
| Barrel outside diameter (D) | 15.6 mm / 0.61 in |
| Barrel inside diameter (C) | 14.8 mm / 0.58 in |
| Barrel material | Copper, tin plated |
| Catalogue current rating | 310 A |
| Compliance | CE and RoHS; not UL Listed |
| Pack quantity | 100 pcs |
The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN95-34 from the conductor’s marked 95 mm² cross-section first, then compare a 34 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.
95 mm² bare ferrule with a 34 mm barrel
The model code is direct: 95 identifies the 95 mm² conductor size and 34 identifies the nominal barrel length in millimetres. HEN95-34 suits terminals that accept a 34 mm barrel.
Compliance and ordering
HEN95-34 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN95-34 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.
Request HEN95-34 pricing
Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.
FAQ
What does HEN95-34 mean?
HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 95 size code identifies the 95 mm² conductor size and 34 denotes a 34 mm barrel.
When is a non-insulated ferrule the right choice?
Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.
Is HEN95-34 UL Listed?
No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.
Is HEN95-34 a bootlace ferrule?
Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.
Which crimp tool covers HEN95-34?
a hydraulic or heavy mechanical crimper covers the 95 mm² range that includes HEN95-34. Verify the finished crimp against the conductor and terminal requirements.
Is HEN95-34 sold individually?
No. The standard factory pack contains 100 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.