HEN120-30

HEN120-30 Non-Insulated Bootlace Ferrule: 120 mm² / 4/0 AWG 30 mm Barrel

The HEN120-30 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 120 mm² stranded conductor where no insulating collar is required.

  • Wire size120 mm² / catalogue reference 4/0 AWG
  • Barrel length30 mm / 1.18 in
  • CollarNone – bare tin plated sleeve
  • Rating360 A catalogue maximum
  • ComplianceCE and RoHS; not UL Listed
  • Pack100 pieces
Verified modelDimensions and pack quantity match the HEN120-30 supplier specification.
Catalogue configurationThe sleeve is shown for catalogue reference; availability, pack quantity and lead time are confirmed by quotation.
Crimp toola hydraulic or heavy mechanical crimper covers the 120 mm² ferrule range.

HEN120-30 wire ferrule dimensions and specifications

Property HEN120-30 value
Product type Non-insulated ferrule / bare bootlace sleeve
Conductor cross-section 120 mm²
Catalogue AWG reference 4/0 AWG
Barrel length (F) 30.0 mm / 1.18 in
Overall length (L) 30.0 mm / 1.18 in
Flare outside diameter (W) 20.2 mm / 0.80 in
Barrel outside diameter (D) 17.7 mm / 0.70 in
Barrel inside diameter (C) 16.7 mm / 0.66 in
Barrel material Copper, tin plated
Catalogue current rating 360 A
Compliance CE and RoHS; not UL Listed
Pack quantity 100 pcs

The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN120-30 from the conductor’s marked 120 mm² cross-section first, then compare a 30 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.


120 mm² bare ferrule with a 30 mm barrel

The model code is direct: 120 identifies the 120 mm² conductor size and 30 identifies the nominal barrel length in millimetres. HEN120-30 suits terminals that accept a 30 mm barrel.

Compliance and ordering

HEN120-30 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN120-30 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.

Request HEN120-30 pricing

Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.

FAQ

What does HEN120-30 mean?

HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 120 size code identifies the 120 mm² conductor size and 30 denotes a 30 mm barrel.

When is a non-insulated ferrule the right choice?

Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.

Is HEN120-30 UL Listed?

No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.

Is HEN120-30 a bootlace ferrule?

Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.

Which crimp tool covers HEN120-30?

a hydraulic or heavy mechanical crimper covers the 120 mm² range that includes HEN120-30. Verify the finished crimp against the conductor and terminal requirements.

Is HEN120-30 sold individually?

No. The standard factory pack contains 100 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.