HEN16-18

HEN16-18 Non-Insulated Bootlace Ferrule: 16 mm² / 6 AWG 18 mm Barrel

The HEN16-18 non-insulated wire ferrule is a bare tin plated copper sleeve for terminating 16 mm² stranded conductor where no insulating collar is required.

  • Wire size16 mm² / catalogue reference 6 AWG
  • Barrel length18 mm / 0.71 in
  • CollarNone – bare tin plated sleeve
  • Rating95 A catalogue maximum
  • ComplianceCE and RoHS; not UL Listed
  • Pack1,000 pieces
Verified modelDimensions and pack quantity match the HEN16-18 supplier specification.
Catalogue configurationThe sleeve is shown for catalogue reference; availability, pack quantity and lead time are confirmed by quotation.
Crimp toolHX-35WF covers the 16 mm² ferrule range.

HEN16-18 wire ferrule dimensions and specifications

Property HEN16-18 value
Product type Non-insulated ferrule / bare bootlace sleeve
Conductor cross-section 16 mm²
Catalogue AWG reference 6 AWG
Barrel length (F) 18.0 mm / 0.71 in
Overall length (L) 18.0 mm / 0.71 in
Flare outside diameter (W) 7.2 mm / 0.28 in
Barrel outside diameter (D) 6.2 mm / 0.24 in
Barrel inside diameter (C) 5.8 mm / 0.23 in
Barrel material Copper, tin plated
Catalogue current rating 95 A
Compliance CE and RoHS; not UL Listed
Pack quantity 1,000 pcs

The AWG value is the supplier catalogue reference, not a mathematical conversion. Select HEN16-18 from the conductor’s marked 16 mm² cross-section first, then compare an 18 mm barrel with the terminal maker’s accepted ferrule and strip-length requirements.


16 mm² bare ferrule with an 18 mm barrel

The model code is direct: 16 identifies the 16 mm² conductor size and 18 identifies the nominal barrel length in millimetres. HEN16-18 suits terminals that accept an 18 mm barrel.

Compliance and ordering

HEN16-18 is not UL Listed. The UL 486F listing covers the HE insulated single-wire series only, and the non-insulated range is outside it. HEN16-18 is supplied with CE and RoHS documentation. If the panel requires a UL Listed ferrule, specify the equivalent HE series instead.

Request HEN16-18 pricing

Send the required quantity and destination. Termnex will confirm current availability, lead time and the documentation supplied with the quoted pack.

FAQ

What does HEN16-18 mean?

HEN identifies the non-insulated ferrule series – a bare tin plated copper sleeve with no collar. The 16 size code identifies the 16 mm² conductor size and 18 denotes an 18 mm barrel.

When is a non-insulated ferrule the right choice?

Where the terminal or enclosure already provides strain relief and insulation, or where collar height would not fit. The colour coding and strain relief of an insulated ferrule are given up in exchange.

Is HEN16-18 UL Listed?

No. The supplier confirms UL 486F covers the HE insulated series only; the HEN non-insulated series is not UL Listed. It is supplied with CE and RoHS documentation.

Is HEN16-18 a bootlace ferrule?

Yes. Wire ferrule, bootlace ferrule, cable ferrule and cord end terminal are common names for this type of stranded-wire termination.

Which crimp tool covers HEN16-18?

HX-35WF covers the 16 mm² range that includes HEN16-18. Verify the finished crimp against the conductor and terminal requirements.

Is HEN16-18 sold individually?

No. The standard factory pack contains 1,000 pieces. Small evaluation quantities and commercial terms are confirmed with the quotation.